E. Dold & Söhne GmbH & Co. KG

Tel.: +49 7723 654-0
E-Mail: dold-relays@dold.com

• Representatives
• Contact form

Direct contact for orders

Tel.: +49 7723 654-454
E-Mail: ab@dold.com

Direct contact for technical questions

Tel.: +49 7723 654-459
E-Mail: rv@dold.com

Direct contact for shipping inquiries

Tel.: +49 7723 654-455
UF 6925

Emergency stop module

UF 6925

Contacts

Nominal voltage

Approvals and Markings

Variant

  • 0067556
  • UF6925.03/61 DC8-36V
The emergency stop module UF 6925 is suitable to protect men and machine by safety related... more

Product description

The emergency stop module UF 6925 is suitable to protect men and machine by safety related enabling or disabling of a safety circuit. It is used in applications with e-stop buttons and safety gates.

Technical specifications

Width: 17,5 mm
Cat. / PL acc. to EN ISO 13849-1: 4/e
SIL CL acc. to IEC/EN 62061: 3
Nominal voltage: DC
Suited as safety gate monitor: Yes
Thermal current Ith max.: 8 A
1- / 2-channel: 2
Cross fault detection: Yes
Connection: Front side cage clamp terminals
Output contacts max.: 3 NO contacts
Approvals: UL
Type: UF 6925

Advantages

  • For safety applications up to PL e / Cat. 4 e.g. SIL 3
  • Space saving
  • Connection front side
  • Manual or automatic start
  • Can be used also for safety gate
  • Line fault detection on On-button

Features

  • Corresponds to
    - PL e and category 4 according to EN ISO 13849-1
    - SIL 3 according to EN 61508
    - maximum SIL 3 according to EN IEC 62061
  • Can be used in applications:
    - According to EN 61511
    - According to EN 50156-1 for furnaces
  • 2-channel operation
  • Forcibly guided output contacts
  • With or without cross fault monitoring in the E-stop loop, switch S1
  • Manual restart or automatic restart, switch S2
  • LED indicator for channel 1, 2 and Netz
  • Width 17,5 mm