E. Dold & Söhne GmbH & Co. KG

Tel.: +49 7723 654-0
E-Mail: dold-relays@dold.com

• Representatives
• Contact form

Direct contact for orders

Tel.: +49 7723 654-454
E-Mail: ab@dold.com

Direct contact for technical questions

Tel.: +49 7723 654-459
E-Mail: rv@dold.com

Direct contact for shipping inquiries

Tel.: +49 7723 654-455
A B C D E F G H I J K L M N O P Q R S T U V W Z

A 13 Posts in this encyclopedia category

Actuator

Actuator, e.g. motor, valve, relay, motor contactor, etc. ...

All-current sensitive

All-current sensitive residual current monitors (type B) use special measuring methods. They are suitable for measuring all types of residual currents in electrical installations: AC currents AC,...

Requirement class (AK)

According to DIN 19250, assignment of requirements for the realisation of the protective device, which should lead to a safety-related performance of the device appropriate to the risk. It...

Start-up interlock

Device that prevents automatic machine start-up when the power supply to the SAG is switched on or interrupted and switched on again.

Start-up test

Manuell oder automatisch durchgeführter Test des SAG, nachdem die Versorgungsspannung an das SAG angelegt wurde. Ein Beispiel ist das manuelle Öffnen und Schließen einer trennenden...

Response delay

The unit is started by applying the operating voltage. After the set delay time has elapsed, the time relay switches to the operating position.

Drive monitoring

The speed monitors of the SAFEMASTER S series detect and signal the standstill and speed of machines and systems in automatic as well as in set-up mode. Dold offers efficient and economical...

Working current principle

The contact switches to the active position when the response condition is fulfilled.

ATEX

ATEX is the abbreviation for "Atmosphère Explosible". ATEX directives guarantee the placing on the market of explosion-protected equipment and protective fence systems including components (EU...

Output expander

SAG, which can only be used in conjunction with a base unit / basic unit for the purpose of multiplying the outputs.

Switch off in an emergency

Emergency action intended to cut off the supply of electrical energy to all or part of an installation if there is a risk of electric shock or any other risk of electrical origin [IEC / DIN EN...

Evaluation unit, safety-related

Generates a safety-related output signal, depending on the status of connected signal transmitters, either according to a fixed assignment or according to programmed instructions. SAG.

Automatic start

After checking the input image and a positive test by the SAG , an enable signal is generated without manual approval. This function is also called dynamic operation and is not permitted for...