Cookie preferences
This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
"Allow all cookies" cookie
"Decline all cookies" cookie
CSRF token
Cookie preferences
Currency change
Customer recognition
Customer-specific caching
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Show the facebook fanpage in the right blod sidebar
Statistics & Tracking
Affiliate program
Google Tag Manager
Track device being used

Insulation monitor
AN 5892/800
- Article number: 0061228
- Variant: AN5892.11/800 UH AC230V 50K
The insulation monitor AN5892/800 of the series VARIMETER IMD monitors the ground resistance of... more
Product description
The insulation monitor AN5892/800 of the series VARIMETER IMD monitors the ground resistance of isolated DC-voltage systems (IT-systems) with directly connected inverters with nominal voltage up to DC 100 ... 1000 V. The unit detects symmetrical as well as unsymmetrical faults. The separate auxiliary supply allows also monitoring when the system is without voltage. To indicate the actual ground resistance value the unit has an LED chain and an analogue output. When a fault is detected the relay switches and the red LED lights up. The device can be used for system with leakage capacities up to 20 μF.
Technical specifications
Width: | 100 mm |
Response value: | 50 kΩ |
IMD type: | DC |
Nominal voltage IT system: | DC 100 - 1000 V |
Auxiliary voltage: | AC |
Enclosure design: | Switch cabinet |
Connection for indicator: | Yes |
Response value type: | Fixed |
Type: | AN 5892/800 |
Downloads
Advantages
- Preventive fire and system protection
- Insulation monitoring of DC-systems with directly connected inverters
up to 1000 V - No additional coupling device required
- Suitable for leakage capacitances up to 20 μF
- Monitoring also with voltage-free mains
Features
- Insulation monitoring according to IEC/EN 61 557-8
- Fixed response value RAN
- Internal reset button
- External reset and test button can be connected
- LED indicator
- 1 changeover contact
- Programmable for manual reset or hysteresis function
- Analogue output for insulating value
- External connection of indicating instrument possible
- De-energized on trip
- Width 100 mm