Dold Italia S.r.l.

Via Privata Passo Pordoi, 5
20139 Milano
Italia
RN 5897/320

Insulation monitor

RN 5897/320

Contacts

Auxiliary voltage

Alarm value

Prewarning value

Approvals and Markings

Variant

  • 0068771
  • RN5897.12/320/61 DC12-24V
The insulation monitor RN 5897/320 of the VARIMETER IMD family is a solution for optimal... altro

Descrizione del prodotto

The insulation monitor RN 5897/320 of the VARIMETER IMD family is a solution for optimal insulation monitoring of modern IT systems. The device can be used in the most flexible way for AC, DC and AC/DC systems. Mains areas of applications are non-earthed DC charging stations for electric vehicles with mains voltages up to DC 1000 V, that need an extended temperature range. The connection to the monitored voltage system is done via one of the coupling units. The setting of the parameters and the switching values is done by simple and operator friendly rotational switches on front of the device. The operating status is indicated user friendly via a multicolour LED. With a sealable transparent cover the device is protectet against manipulation.

Specifiche tecniche

Width: 52,5 mm
Classification: For DC charging stations
Response value: 1 - 100 kΩ
IMD type: AC, DC, AC/DC
Nominal voltage IT system: AC 0 - 690 (Coupling device), DC 0 - 1000 (Coupling device) V
Auxiliary voltage: DC, AC/DC
Earth fault indicator: Yes
Approvals: UL
Response value type: Adjustable
Enclosure design: Distribution board
Type: RN 5897/320

Vorteile / Kundennutzen

  • Suitable for DC charging stations for electric vehicles acc. to IEC/EN 61851-23:2014/AC:2016-06
  • Insulation monitoring according to IEC/EN 61557-8
  • Connection of an external coupling device RL 5898 for voltages up to AC 400 V / DC 500 V or RP 5898 for voltages up to AC 690 V / DC 1000 V
  • Extended operating temperature range of - 40 ... + 70 °C
  • Very fast reaction time ≤ 1 s
  • Optimised insulation resistance monitoring also during mains voltage variation
  • Self-test every full operating hours
  • Preventive fire and system protection
  • Detection of symmetric and asymmetric insulation faults
  • Universal application in non-earthed AC, DC, AC/DC networks
  • Easy adjustment of response values and setting parameter via rotational switch
  • Suitable for large leakage capacitances up to 5 μF
  • Monitoring also with voltage-free mains
  • Measuring circuit L1(+)/L2(-) with broken wire detection (can be switched off)
  • Protective conductor PE1/PE2 with broken wire detection (can't be switched off)

Merkmale

  • 2 separate adjustable response thresholds (using e.g. for pre-alarm and Alarm)
  • Setting range of 1st response value (Pre-alarm): 20 kΩ … 500 kΩ
  • Setting range of 2nd response value (alarm): 1 kΩ … 100 kΩ
  • 1 changeover contacts each for insulation failures-Pre-alarm and -alarm
  • Energized or de-energized on trip can be selected for indicator relay
  • With multicolour status LED to indicate the state of operation.
  • Automatic and manual device self-test
  • Alarm storage selectable
  • Protection against manipulation by sealable transparent cover
  • External control input for combined test- / reset-button with additional Stop of the measuring function
  • 3 wide voltage input for auxiliary voltage
  • Additional coupling device is necessary
  • Width 52.5 mm