Reversing contactor with softstart and active power monitoring
BI 9254
- Reversing operation for door and gate controls, bridge drives and lifting applications with monitoring of blockage
- Conveyor systems with monitoring of blockage
- Actuating drives in process controls with blockage monitoring
| Comando digitale (ON/OFF): | DC |
|---|---|
| Controllo della temperatura: | Yes |
| Corrente di carico fino a: | 12 A |
| Forma costruttiva dell'involucro: | Switch cabinet |
| Larghezza: | 90 mm |
| Numero di poli: | 3-pole |
| Omologazioni: | UL |
| Tensione di carico fino a: | 3AC 400 V |
| Uscita di segnalazione: | Yes |
| Tipo di apparecchio: | BI 9254 |
- According to IEC/EN 60947-1, IEC/EN 60947-4-2
- To reverse 3 phase motors
- Electrical interlocking of both directions
- 2-phase softstart
- Active power monitoring after softstart
- Temperature monitoring of power semiconductors
- LED indicator
- Internal auxiliary voltage are made from phase voltage
- Galvanic separation of control circuit and power circuit
- Space and cost saving with 3 functions in one compact unit
- Reducing of wiring and wiring failure
- Width 90 mm