Emergency stop module
BD 5987
The BD 5987 is used to interrupt a safety circuit in a safe way. It can be used to protect people and machines in applications with e-stop buttons and safety gates. The BD 5987.02/301 can be used as electronic replacement of a safety switch according to EN 81-20, section 5.11.2.2.
| 1 / 2 canali: | 1, 2 |
|---|---|
| Adatto come controllo per porte di sicurezza: | Yes |
| Cat. / PL secondo EN ISO 13849-1: | 4/e |
| Contatti di uscita max.: | 2 NO contacts |
| Corrente termica Ith max.: | 10 A |
| Larghezza: | 45 mm |
| Omologazioni: | UL-Recognized |
| Rilevamento corto circuito trasversale: | Yes |
| SIL CL secondo IEC/EN 62061: | 3 |
| SIL secondo IEC/EN 62061: | 3 |
| Tecnica di collegamento: | Screw terminals |
| Tensione nominale: | AC, DC |
| Tipo di apparecchio: | BD 5987 |
- Safe disconnection of electrical circuits
- Line fault detection at On pushbutton
- Gold-plated contacts to switch small loads (input for PLC)
- Optionally cross fault detection in emergency stop circuit
- According to
- PL e and category 4 to EN ISO 13849-1
- maximum SIL 3 to EN IEC 62061
- SIL 3 to EN 61508 - Output: 2 NO contacts for AC 250 V
- 1-channel or 2-channel connection
- LED displays for channels 1 and 2
- Overvoltage and short circuit protection
- Wire connection: also 2 x 1,5 mm2 stranded ferruled (isolated), DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
- Width 45 mm
- BD 5987._ _/001: same as BD 5987._ _ but
- Optionally automatic On function or after activation by the On pushbutton
- Optionally cross fault detection in emergency stop circuit
- BD 5987.02/301: same as BD 5987.02/001 but
- Suitable also for elevators according to EN 81-20/-50
- Complies to the requirements of the directive 2014/33/EU for elevators
- According to
- PL d and category 3 to EN ISO 13849-1
- maximum SIL 2 to EN IEC 62061
- SIL 2 to EN 61508 - Shorter release time when opening the supply circuit
- Single-channel e-stop circuit