Safety module for elevator controls
LG 5925/034
Bridging of the door and locking switches while moving the elevator in the unlocking zone with open doors according to EN81-20/-50 for elevators for people and loads.
| 1 / 2 canali: | 1, 2 |
|---|---|
| Cat. / PL secondo EN ISO 13849-1: | 4/e |
| Contatti di uscita max.: | 1 NC contact, 3 NO contacts |
| Corrente termica Ith max.: | 5 A |
| Larghezza: | 22,5 mm |
| Rilevamento corto circuito trasversale: | Yes |
| SIL CL secondo IEC/EN 62061: | 3 |
| SIL secondo IEC/EN 62061: | 3 |
| Tecnica di collegamento: | Pluggable cage clamp terminals, Pluggable screw terminals, Screw terminals |
| Tensione nominale: | AC/DC |
| Tipo di apparecchio: | LG 5925/034 |
- For elevators according to EN 81-20/-50
- According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
- Directive 2014/33/EU for elevators - Output: 3 NO contacts, 1 NC contact
- Single or 2-channel operation
- Line fault detection on On-button
- Manual restart or automatic restart, switch S2
- With or without cross fault monitoring in the loop, switch S1
- LED indicator for channel 1, 2 and supply voltage
- Degree of protection IP40; can be mounted in cabinets and installations with lower degree of protection without additional measures (depending on ambient conditions)
- Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated), DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
- As option with pluggable terminal blocks for easy exchange of devices
- With screw terminals
- Or with cage clamp terminals - Width 22.5 mm