Emergency stop module with time delay
LG 5928
- Protection of people and machines
- Emergency stop circuits on machines, Stop category 1 can be realised
- Monitoring of safety gates
| 1 / 2 canali: | 1, 2 |
|---|---|
| Adatto come controllo per porte di sicurezza: | Yes |
| Cat. / PL secondo EN ISO 13849-1: | 4/e |
| Contatti di uscita max.: | 1 NO contact delayed, 2 NO contacts |
| Corrente termica Ith max.: | 8 A |
| Corrente termica Ith max.: | 8 |
| Larghezza: | 22,5 mm |
| Omologazioni: | UL |
| Rilevamento corto circuito trasversale: | Yes |
| SIL CL secondo IEC/EN 62061: | 3 |
| SIL secondo IEC/EN 62061: | 3 |
| Tecnica di collegamento: | Pluggable cage clamp terminals, Pluggable screw terminals, Screw terminals |
| Tensione nominale: | DC |
| Tipo di apparecchio: | LG 5928 |
- Compact, flexible and safe
- Short response time
- Ideal for designs according to the new safety standards
- According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511 - Output: 2 NO instantaneous contacts and 1 release delay contact
- 1- or 2-channel connection
- Line fault detection at the ON pushbuttons at connection on terminals S33-S34
- Manual restart with button on S33-S34 or automatic restart with bridge between S13-S34
- With or without cross fault monitoring in the E-stop loop
- Indication for released time circuit
- LED indication for supply, channel 1/2 and release delayed contacts
- Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated), DIN 46228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46228-1/-2/-3
- As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals - Width 22.5 mm