UH 6932

Speed monitor

UH 6932

Contacts

Auxiliary voltage

Terminal type

Approvals and Markings

Variant

  • 0066816
  • UH6932.02PS/61 DC24V
The speed monitor UH 6932 provides safe monitoring of motors and rotating equipment. It is used... altro

Descrizione del prodotto

The speed monitor UH 6932 provides safe monitoring of motors and rotating equipment. It is used in machines and plants where machine movements or moving parts can be a danger to men and machine. Using the front side display the parameters can be easily and comfortably adapted to the individual application or changed when necessary.

Specifiche tecniche

Width: 45 mm
Classification: For initiators and encoders
Cat. / PL acc. to EN ISO 13849-1: 4/e
SIL CL acc. to IEC/EN 62061: 3
Nominal voltage: DC
Thermal current Ith max.: 8 A
1- / 2-channel: 2
Connection: Pluggable screw terminals, Pluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire
Indicator contacts: 2 Semiconductor monitoring outputs
Approvals: UL
Forcibly guided output contacts max.: 2 NO contacts
Type: UH 6932

Vorteile / Kundennutzen

  • For safety applications up to PL e / Cat. 4 and SIL 3
  • Simple and time saving setup without PC
  • Comfortable, menu guided configuration via frontside display
  • Reducing interruption time in production by extensive diagnostic functions
  • Easy to integrate in existing drive applications
  • Possible languages: English, german, french

Merkmale

  • Corresponds to
    - PL e and category 4 according to EN ISO 13849-1
    - SIL 3 according to EN 61508
  • Can be used in safety applications as follows:
    - Up to maximum SIL 3 according to EN IEC 62061
    - Up to SIL 3 according to EN 61511
  • Overspeed, underspeed or window monitoring
  • Integrated user friendly frontside display
    - Comfortable, menu guided configuration
    - For set point and actual value of Hz
  • Fast reaction time by measuring duration of cycle of input frequency
  • For PNP- or NPN-sensors
  • Adjustable hysteresis
  • Adjustable reset delay function from 0 ... 100 s
  • Adjustable start up time delay from 0 ... 100 s
  • Adjustable alarm delay from 0 ... 100 s
  • Manual or auto-reset
  • 2-channel function
  • Forcibly guided output contacts
  • LED-indicators and 2 semiconductor monitoring output
  • Width 45 mm
  • With pluggable terminal blocks for easy exchange of devices
  • Variant /_ _1:
    - It is possible to set a variety of response parameters by means of a 4 bit selection facility from an overriding control unit;
    - Analog output (2 V to 10 V) corresponding to the current speed;
    - The possibility of overriding the speed by a supervisory function (muting);
    - Adjustable switchover time from 0 ... 100 s