Multifunctional safety module
UG 6970
The multifunctional safety module UG 6970 provides protection of men and machines by enabling and disabling a safety circuit. It is used together with e-stop buttons, safety gates, light curtains with self testing (type 4) to IEC/EN 61496-1, 2-hand buttons on presses for metal processing and productions machines with dangerous closing movements (type III C to EN ISO 13851) and safety mats, edges and tape switches. Simply select 2 out of 6 safety functions on rotary switches - ready. This reduces divers types of safety modules in stock and simplifies your disposition.
| 1 / 2 canali: | 2 |
|---|---|
| Applicazione: | Emergency stop, Light barrier, Safety gate, Safety mat, Two-hand |
| Cat. / PL secondo EN ISO 13849-1: | 4/e |
| Contatti di uscita sicuri, contatti NA ridondanti: | 4 |
| Corrente termica Ith max.: | 8 A |
| Corrente termica Ith max.: | 8 |
| Larghezza: | 22,5 mm |
| Omologazioni: | UL |
| Rilevamento corto circuito trasversale: | Yes |
| SIL CL secondo IEC/EN 62061: | 3 |
| SIL secondo IEC/EN 62061: | 3 |
| Tecnica di collegamento: | Pluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire, Pluggable screw terminals |
| Tensione nominale: | DC |
| Tipo di apparecchio: | UG 6970 |
- 2 independent, separately adjustable safety funcions:
- E-Stop
- Safety gate
- Two-hand control
- Safety mat / Safety edge
- Exclusive or contacts
- Light curtain - Only one device, two safety functions at the same time
- Manual or auto start
- Protection against manipulation by sealable transparent cover
- According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511 - Acc. to EN 50156-1 for furnaces
- Line fault detection on On-button:
- Manual restart or automatic restart
- With or without cross fault monitoring
- 2-channel
- Forcibly guided output contacts
- Output: 2 NO contacts per safety function
- 1 semiconductor output per safety function
- LED indicator for operation, safety function 1, 2 and failure
- As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals - Width: 22.5 mm