Emergency stop module BD 5935 The BD 5935 is used to interrupt a safety circuit in a safe way. It can be used to protect people and machines in applications with e-stop buttons and safety gates. Advantages . Safe disconnection of electrical circuits . Line fault detection on ON pushbutton . Gold plated contacts to switch low loads (signal to PLC) . Optionally cross fault detection in emergency stop circuit . Easy exchange of devices by removable terminal strips Features . According to - Performance Level (PL) e and category 4 to EN ISO 13849-1 - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061 - Safety Integrity Level (SIL 3) to IEC/EN 61508 . 1- or 2-channel connection . Operating state display . LED display for channels 1 and 2 . Overvoltage and short circuit protection . Wire connection: also 2 x 1.5 mm² stranded ferruled (isolated), DIN 46228-1/-2/-3/-4 or 2 x 2.5 mm² stranded ferruled DIN 46228-1/-2/-3 . Output: optionally 1 NO / 1 NC or 3 NO / 1 NC contacts . Optionally automatic ON function or activation via the ON pushbutton . With fast auto start as option . Width 45 mm Technical specifications Suited as safety gate monitor: Yes Cat. / PL acc. to EN ISO 13849-1: 4/e 1- / 2-channel: 1, 2 Connection: Pluggable screw terminals Output contacts max.: 1 NC contact, 3 NO contacts Width: 45mm Cross fault detection: Yes SIL CL acc. to IEC/EN 62061: 3 Approvals: UL-Recognized Nominal voltage: AC, DC Thermal current Ith max.: 10A Type: BD 5935 Manufacturer: E. Dold & Söhne GmbH & Co. KG Type: BD5935.48 AC230V 50/60Hz Art. No.: 0045453