Emergency stop module BG 5925 . Protection of people and machines . Emergency stop circuits on machines . Monitoring of safety gates Features . According to - PL e and category 4 to EN ISO 13849-1 - maximum SIL 3 to EN IEC 62061 - SIL 3 to EN 61508 . Output: max. 3 NO contacts, see contacts . Single and 2-channel operation . Line fault detection on On-button . Manual restart or automatic restart, switch S2 . With or without cross fault monitoring in the E-stop loop, switch S1 . LED indicator for channel 1 and 2 and Power . Removable terminal strips . Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated), DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3 . Width 22.5 mm Technical specifications Suited as safety gate monitor: Yes Cat. / PL acc. to EN ISO 13849-1: 4/e 1- / 2-channel: 1, 2 Connection: Pluggable screw terminals Output contacts max.: 4 NO contacts Width: 22,5mm Cross fault detection: Yes SIL CL acc. to IEC/EN 62061: 3 Approvals: UL Nominal voltage: DC, AC/DC Thermal current Ith max.: 5A Type: BG 5925 Manufacturer: E. Dold & Söhne GmbH & Co. KG Type: BG5925.02/61 DC24V Art. No.: 0047868