Safety edge module LG 5944 The safety edge module LG 5944 monitors safety edges with a permittedswitching current of ≥ 10mA. It enables or disables a safety circuit and can be used to protect men and machine. To avoid a damage of the safety edges by excessive currents, the current provided by the LG 5944 is limited to 10 mA even in the case of a short circuit. Advantages . Current limitation protects the connected safety edge against electrical destruction by overcurrent and short circuit . Universal usage with safety edges with different allowed switching currents (also for lower switching currents) . Pluggable terminal blocks for easy exchange Features . According to - Performance Level (PL) e and category 3 to EN ISO 13849-1 - SIL Claimed Level (maximum SIL) 3 to IEC/EN 62061 - Safety Integrity Level (SIL) 3 to IEC/EN 61508 . Output: 2 redundant safety outputs . Line fault detection on On-button . Manual restart or automatic restart, switch S2 . Indication for operating condition . LED indicator for channel 1 and 2 . As option with pluggable terminal blocks for easy exchange of devices - With screw terminals - Or with cage clamp terminals . Width: 22.5 mm Technical specifications Cat. / PL acc. to EN ISO 13849-1: 4/e 1- / 2-channel: 2 Connection: Screw terminals, Pluggable screw terminals, Pluggable cage clamp terminals Output contacts max.: 2 NO contacts Width: 22,5mm SIL CL acc. to IEC/EN 62061: 3 Approvals: UL Nominal voltage: AC/DC Thermal current Ith max.: 5A Type: LG 5944 Manufacturer: E. Dold & Söhne GmbH & Co. KG Type: LG5944.02PC/61 AC/DC24V Art. No.: 0059038