Emergency stop module UF 6925 The emergency stop module UF 6925 is suitable to protect men and machine by safety related enabling or disabling of a safety circuit. It is used in applications with e-stop buttons and safety gates. Advantages . For safety applications up to PL e / Cat. 4 e.g. SIL 3 . Space saving . Connection front side . Manual or automatic start . Can be used also for safety gate . Line fault detection on On-button Features . Corresponds to - PL e and category 4 according to EN ISO 13849-1 - SIL 3 according to EN 61508 - maximum SIL 3 according to EN IEC 62061 . Can be used in applications: - According to EN 61511 - According to EN 50156-1 for furnaces . 2-channel operation . Forcibly guided output contacts . With or without cross fault monitoring in the E-stop loop, switch S1 . Manual restart or automatic restart, switch S2 . LED indicator for channel 1, 2 and Netz . Width 17,5 mm Technical specifications Suited as safety gate monitor: Yes Cat. / PL acc. to EN ISO 13849-1: 4/e 1- / 2-channel: 2 Connection: Front side cage clamp terminals Output contacts max.: 3 NO contacts Width: 17,5mm Cross fault detection: Yes SIL CL acc. to IEC/EN 62061: 3 Approvals: UL Nominal voltage: DC Thermal current Ith max.: 8A Type: UF 6925 Manufacturer: E. Dold & Söhne GmbH & Co. KG Type: UF6925.03/61 DC8-36V Art. No.: 0067556