Insulation monitor LK 5896 The insulation monitor LK 5896 of the VARIMETER IMD family is a solution for optimal insulation monitoring of modern IT systems. The device can be used in the most flexible way for AC, DC and AC/DC systems even with large leakage capacity to earth (PE). The adjustment of the setting values is simple and user friendly done on 2 rotary switches on the front of the device. Via LEDs the measured value, device parameters and device status are indicated easy to read. The unit has 3 relay contacts to signal Insulation and device failures. The analogue output provides a voltage and current signal proportional to the actual insulation resistance, which can be connected to a superior control (plc), another system or external display unit. In addition the LK 5896 provides a second measuring circuit that can be used to monitor an inverter on the AC side also when the inverter is disconnected. Advantages . Preventive fire and system protection . Quick fault localisation through selective earth fault detection to L+ and L- . Universal application in non-earthed AC, DC, AC/DC networks with up to 1000 V nominal voltage . Suitable for large leakage capacitances up to 3000 μF . Simplest setting via engaging rotary switches . For monitoring photovoltaic system, also with thin-film technology . Optimised measuring times - normally shorter than with known methods . Monitoring also with voltage-free mains . Additional measuring circuit allows AC output monitoring even with the inverter switched off, e.g. with hybrid vehicles . Measuring circuit with broken wire detection . No additional coupling device required . Trigger output for insulation fault locating system . Analogue output for value of the insulation resistance: 0 ... 10 V / 0 ... 20 mA (2 ... 10 V / 4 ... 20 mA) Features . Insulation monitoring according to IEC/EN 61557-8 . Detection of symmetric and asymmetric insulation faults . Measuring circuits can be disconnected via control terminals, e.g. for mains couplings . 1 changeover contact each for prewarning and alarm . 3. output relay for signalling wire break and device faults . Prewarning threshold setting range: 20 kΩ ... 2 MΩ . Alarm threshold setting range: 1 kΩ ... 250 kΩ . Energized or de-energized on trip can be selected for output relay . Setting the maximum leakage capacitance to shorten the response time . Simple, clearly arranged adjustment of the device with screwdriver . LED chain to indicate the current insulation resistance . Display of active measuring circuits . Automatic and manual device self-test . Alarm storage selectable . External test and reset pushbutton can be connected . Width: 90 mm Technical specifications Width: 90mm Approvals: UL Enclosure design: Switch cabinet IMD type: AC, DC, AC/DC Nominal voltage IT system: AC 0 - 1000, DC 0 - 1000V Response value type: Adjustable Response value: 1 - 250kΩ Earth fault indicator: Yes Auxiliary voltage: DC Connection for indicator: Yes Classification: For photovoltaic systems Type: LK 5896 Manufacturer: E. Dold & Söhne GmbH & Co. KG Type: LK5896.13/100/61 DC24V 1k-250k Art. No.: 0065131