Input module BG 5914.08/_0___ Realization of fail-safe control circuits for protection of people and machinery The modules BG 5914 and BH 5914 have been developed for applications in which numerous one-channel Emergency stop contacts have to be monitored. Features . According to: - Performance Level (PL) d and category 2 to EN ISO 13849-1: 2008 - SIL Claimed Level (SIL CL) 2 to IEC/EN 62061 - Safety Integrity Level (SIL 2) to IEC/EN 61508 . Input module for realization of: - 8 E-STOP, single-channel, autostart - 6 E-STOP, single-channel, + 1 E-STOP, 2-channel, autostart - 5 E-STOP, single-channel, + 1 -STOP, 2-channel + 1 signal inut, autostart - 8 E-STOP, single-channel, manual start - 6 E-STOP, single-channel, + 1 E-STOP, 2-channel, manual start - 5 E-STOP, single-channel, + 1 E-STOP, 2-channel + 1 signal input, manual start - As an alternative to the 2-channel E-STOP, a light curtain (LC type 4) according to EN 61496-1 can be connected. . Broken wire and short circuit monitoring function with error indication . 2 semiconductor outputs per function module for status indication . LEDs for status indication . Width: 22.5 mm (BG 5914) or 45 mm (BH 5914) Technical specifications Cat. / PL acc. to EN ISO 13849-1: 2/d Width: 22,5mm SIL CL acc. to IEC/EN 62061: 2 Application: Light barrier, Emergency stop Type: BG 5914.08/_0___ Manufacturer: E. Dold & Söhne GmbH & Co. KG Type: BG5914.08/00MF0 DC24V Art. No.: 0056633