Cookie preferences
This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
"Allow all cookies" cookie
"Decline all cookies" cookie
CSRF token
Cookie preferences
Currency change
Customer recognition
Customer-specific caching
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Show the facebook fanpage in the right blod sidebar
Statistics & Tracking
Affiliate program
Google Tag Manager
Track device being used
Insulation monitor
RP 5888
- Article number: 0060656
- Type: RP5888.12 AC/DC24-80V 5K...5M-OHM
The insulation monitor RP 5888 of the VARIMETER IMD family provides best and up to date... more
Product description
The insulation monitor RP 5888 of the VARIMETER IMD family provides best and up to date insulation monitoring of AC-IT systems. The measuring principle is overlay with DC-measuring voltage. The setting of the parameters and the switching values is done by simple and operator friendly rotational switches on front of the device. The operating status is indicated user friendly via three multicolour LEDs. In addition the actual insulation resistance value is available on an analogue output.
Technical specifications
Width: | 70 mm |
Response value: | 5 - 5000 kΩ |
IMD type: | AC |
Nominal voltage IT system: | AC 0 - 500 V |
Auxiliary voltage: | AC/DC |
Earth fault indicator: | Yes |
Connection for indicator: | Yes |
Response value type: | Adjustable |
Enclosure design: | Distribution board |
Type: | RP 5888 |
Features
- Increasing the availability of machines and plants
- For preventive maintenance
- According to IEC/EN 61 557-8
- With configurable analogue output for insulating value
- For three-phase and A.C. power systems with 0 ... 500 V and 10 ... 1000 Hz
- Adjustable alarm value for ground fault RAL of 5 k ... 5 MΩ
- Monitors also disconnected voltage systems
- Energized / de-energized on trip settable
- Measuring circuit, auxiliary voltage, output contacts and analogue output are galvanically separated
- Programmable for manual reset or hysteresis function
- With test and reset button
- Connections for external test and reset buttons possible
- LED indicators for operation and alarm
- 2 changeover contacts
- Output function programmable