Cookie preferences
This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
"Allow all cookies" cookie
"Decline all cookies" cookie
CSRF token
Cookie preferences
Currency change
Customer recognition
Customer-specific caching
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Show the facebook fanpage in the right blod sidebar
Statistics & Tracking
Affiliate program
Google Tag Manager
Track device being used
Overcurrent Relay
SP 9270
- Article number: 0054253
- Type: SP9270.12 AC/DC24V 0,5-5A 0,1-20S
The overcurrent relay is suitable for monitoring currents in three-phase and alternating current... more
Product description
The overcurrent relay is suitable for monitoring currents in three-phase and alternating current networks. When the switching point is exceeded, the relays changed their state after the time lapse. Due to the adjustable switching point, the relays are universally applicable. By means of the adjustable time delay, current peaks can be taken into account or faded out if required. Readiness for operation and overcurrent are each signaled via an LED.
Technical specifications
Width: | 70 mm |
1- / 3-phase: | 3 |
Measuring range: | AC 0,1 - 15 A |
Auxiliary voltage: | AC, AC/DC |
Operate delay: | Yes |
Output contacts: | 2 C/O contacts |
Enclosure design: | Switch cabinet |
Type: | SP 9270 |
Downloads
Features
- According to IEC/EN 60255-1
- IP 9270, SP 9270CT: 3-phase
IK 9270, SK 9270, IL 9270, SL 9270CT: single phase - Measuring ranges from 0.1 ... 100 A
- Settable response value
- Fixed hysteresis
- Settable time delay
- De-energized on trip
- Energized on trip
- LED indicators
- With auxiliary voltage
- Auxiliary supply and measuring input galvanic separated
- Devices available in 2 enclosure versions:
- I-model, e.g. IK _ _ _ _, depth 61 mm with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43 880
- S-model, e.g. SK _ _ _ _, depth 100 mm with terminals at the top for cabinets with mounting plate and cable duct - Width IK 9270, SK 9270: 17.5 mm
IL 9270, SL 9270CT: 35 mm
IP 9270, SP 9270CT: 70 mm