Cookie preferences
This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
"Allow all cookies" cookie
"Decline all cookies" cookie
CSRF token
Cookie preferences
Currency change
Customer recognition
Customer-specific caching
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Show the facebook fanpage in the right blod sidebar
Statistics & Tracking
Affiliate program
Google Tag Manager
Track device being used

Residual current monitor, Type A
IL 5882
- Article number: 0055137
- Type: IL5882.38 AC/DC12V 10A tv=5S
Detection of insulation faults in grounded voltage systems. The residual current relay is used... more
Product description
Detection of insulation faults in grounded voltage systems. The residual current relay is used to maintain electrical plants before faults occur. Decrease in insulation can be detected and indicated early without interruption of operation.
Technical specifications
Width: | 35 mm |
Adjustable measuring ranges: | 0,01 - 10, 0,01 - 30 A |
Operate delay: | Yes |
Classification: | Type A (AC, DC pulsating) |
Type of voltage: | AC, DC pulsating |
Broken conductor detection: | Yes |
Clear key: | Yes |
Test key: | Yes |
Relay contact / output: | Yes |
Enclosure design: | Distribution board |
Type: | IL 5882 |
Downloads
Advantages
- Preventive fire and system protection
- Increasing the availability of plants by early fault detection
- As option with external or internal residual current transformer
- Protection against manipulation by sealable transparent cover over setting switches
Features
- According to IEC/EN 62020
- for AC and pulsating DC currants Type A to IEC/TR 60755
- 9 tripping values from 10 mA to 10 A or from 10 mA ... 30 A
- Frequency range 20 ... 2000 Hz
- Selection of manual or automatic reset
- With prewarning
- With test and reset button
- Broken wire detection
- Short reaction time
- With adjustable delay tv
- De-energized on trip
- LED indication for auxiliary supply and state of contact
- 2 x 1 changeover contact
- Devices available in 3 enclosure versions:
IL 5882: 63 mm deep with terminals near to the bottom to be mounted in consumer units or industrial distribution systems according to DIN 43880
- Width 35 mm
- For connection of external residual current transformer, e. g. ND 5016, ND 5019 or split current transformer ND 5014
SL 5882: 100 mm deep with terminals near to the top to be mounted in cabinets with mounting plate and cable ducts
- Width 35 mm
- For connection of external residual current transformer, e. g. ND 5016, ND 5019 or split current transformer ND 5014
IR 5882: 63 mm deep with terminals near to the bottom to be mounted in consumer units or industrial distribution systems according to DIN 43880
- Width 105 mm