E. Dold & Söhne GmbH & Co. KG

Tel.: +49 7723 654-0
E-Mail: dold-relays@dold.com

• Representatives
• Contact form

Direct contact for orders

Tel.: +49 7723 654-454
E-Mail: ab@dold.com

Direct contact for technical questions

Tel.: +49 7723 654-459
E-Mail: rv@dold.com

Direct contact for shipping inquiries

Tel.: +49 7723 654-455
UG 6980

Multifunctional safety module

UG 6980

Contacts

Nominal voltage

Terminal type

Approvals and Markings

Variant

  • 0065427
  • UG6980.02PS/61 DC24V
The multifunctional safety module UG 6980 provides protection of men and machines by enabling... more

Product description

The multifunctional safety module UG 6980 provides protection of men and machines by enabling and disabling a safety circuit. It is used together with e-stop buttons, safety gates, light curtains with self testing (type 4) to IEC/EN 61496-1, 2-hand buttons on presses for metal processing and productions machines with dangerous closing movements (type III C to EN ISO 13851) and safety mats, edges and tape switches. Simply select 1 out of 6 safety functions on rotary switches - ready. This reduces divers types of safety modules in stock and simplifies your disposition.

Technical specifications

Width: 22,5 mm
Cat. / PL acc. to EN ISO 13849-1: 4/e
SIL CL acc. to IEC/EN 62061: 3
Nominal voltage: DC
Thermal current Ith max.: 8 A
1- / 2-channel: 2
Application: Emergency stop, Light barrier, Safety mat, Safety gate, Two-hand
Cross fault detection: Yes
Connection: Pluggable screw terminals, Pluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire
Safe output contacts, redundant NO contacts: 2
Approvals: UL
Type: UG 6980

Advantages

  • Adjustable safety functions:
    - E-Stop
    - Safety gate
    - Two-hand control
    - Safety mat / Safety edge
    - Exclusive or contacts
    - Light curtain
  • Manual or auto start
  • Only one device, different safety functions
  • Protection against manipulation by sealable transparent cover

Features

  • According to
    - Performance Level (PL) e and category 4 to EN ISO 13849-1
    - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    - Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
  • Acc. to EN 50156-1 for furnaces
  • Line fault detection on On-button:
  • Manual restart or automatic restart
  • With or without cross fault monitoring
  • 2-channel
  • Forcibly guided output contacts
  • Output: max. 4 NO instantaneous semiconductor monitoring output
  • LED indicator for operation, delay contects and failure
  • As option with pluggable terminal blocks for easy exchange of devices
    - with screw terminals
    - or with cage clamp terminals
  • Width: 22.5 mm