Input module

BG 5913.08/_2___

Contacts

Nominal voltage

Approvals and Markings

Variant

  • 0056805
  • BG5913.08/02MF0 DC24V
Realization of fail-safe control circuits for protection of people and machinery. more

Product description

Realization of fail-safe control circuits for protection of people and machinery.

Technical specifications

Width: 22,5 mm
Cat. / PL acc. to EN ISO 13849-1: 4/e
SIL CL acc. to IEC/EN 62061: 3
Application: Emergency stop, Light barrier, Safety gate, Two-hand
Safety integrity level according to EN 574: lll C
Type: BG 5913.08/_2___

Features

  • According to
    - Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
    - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    - Safety Integrity Level (SIL 3) to IEC/EN 61508
  • Input module for combination of 4 of the following functions to be set
    via rotary switch:
    - safety gate monitoring function (2 x 2 changeover contacts)
    - Light curtain (LC type 4) with manual or automatic start
    - Emergency stop (2-channel) with manual or automatic start
    - Two-hand controls type IIIC acc. to DIN/EN 574
  • Functions can be selected via rotary switches
  • 8 inputs for safety sensors
  • Broken wire and short circuit monitoring function with error indication
  • 2 semiconductor outputs for status indication
  • LEDs for status indication
  • Width: 22.5 mm