Emergency stop modules
Emergency stop modules, often referred to as emergency stop relays,
are suitable for monitoring safety functions such as emergency stop or
safety gate in almost any application. The emergency stop modules are
characterized by maximum safety for man and machine with minimum space
requirements and fulfill all criteria up to Performance Level (PL) e /
Category 4 according to DIN EN ISO 13849. The emergency stop relays
ensure that in the event of danger, dangerous movements on machines and
systems are stopped or energy is switched off. This provides reliable
protection for man and machine. The compact emergency stop relays can be
integrated into the control cabinet in an extremely space-saving manner
and allow time-saving wiring thanks to the plug-in push-in spring-cage
terminals. The SAFEMASTER series of emergency stop relays is
characterized by a large selection of variants and functions for a wide
range of applications.Classic emergency stop modules for emergency stop monitoring to safeguard people and machinery - SAFEMASTER
Highlights
- Up to cat. 4 / PL e or SIL 3
- Outputs with forcibly guided contacts
- Minimum overall width from 17.5 mm
- Use in firing systems according to EN 50156-1
- Variable connection technology
- Fast diagnosis by LED
- Different enclosure designs
Product Finder
- 1- / 2-channel: 1 , 2
- Approvals: UL-Recognized
- Cat. / PL acc. to EN ISO 13849-1: 4/e
- Nominal voltage: AC , DC
- SIL CL acc. to IEC/EN 62061: 3
- Thermal current Ith max.: 10 A
- Width: 45 mm
- 1- / 2-channel: 1 , 2
- Approvals: UL-Recognized
- Cat. / PL acc. to EN ISO 13849-1: 4/e
- Nominal voltage: AC , DC
- SIL CL acc. to IEC/EN 62061: 3
- Thermal current Ith max.: 10 A
- Width: 45 mm
- 1- / 2-channel: 1 , 2
- Approvals: UL-Recognized
- Cat. / PL acc. to EN ISO 13849-1: 4/e
- Nominal voltage: AC , AC/DC , DC
- SIL CL acc. to IEC/EN 62061: 3
- Thermal current Ith max.: 5 A
- Width: 22,5 mm
- 1- / 2-channel: 1 , 2
- Approvals: UL
- Cat. / PL acc. to EN ISO 13849-1: 4/e
- Nominal voltage: AC/DC , DC
- SIL CL acc. to IEC/EN 62061: 3
- Thermal current Ith max.: 5 A
- Width: 22,5 mm
- 1- / 2-channel: 1 , 2
- Approvals: UL
- Cat. / PL acc. to EN ISO 13849-1: 4/e
- Nominal voltage: DC
- SIL CL acc. to IEC/EN 62061: 3
- Thermal current Ith max.: 5 A
- Width: 45 mm
- 1- / 2-channel: 1 , 2
- Approvals: UL
- Cat. / PL acc. to EN ISO 13849-1: 4/e
- Nominal voltage: AC/DC , DC
- SIL CL acc. to IEC/EN 62061: 3
- Thermal current Ith max.: 5 A
- Width: 45 mm
- 1- / 2-channel: 1 , 2
- Cat. / PL acc. to EN ISO 13849-1: 4/e
- Nominal voltage: AC
- SIL CL acc. to IEC/EN 62061: 3
- Thermal current Ith max.: 5 A
- Width: 90 mm
- 1- / 2-channel: 1 , 2
- Cat. / PL acc. to EN ISO 13849-1: 4/e
- Nominal voltage: AC , DC
- SIL CL acc. to IEC/EN 62061: 3
- Thermal current Ith max.: 10 A
- Width: 100 mm
- 1- / 2-channel: 1 , 2
- Cat. / PL acc. to EN ISO 13849-1: 4/e
- Nominal voltage: AC , DC
- SIL CL acc. to IEC/EN 62061: 3
- Thermal current Ith max.: 10 A
- Width: 100 mm
- 1- / 2-channel: 1 , 2
- Approvals: UL-Recognized
- Cat. / PL acc. to EN ISO 13849-1: 4/e
- Nominal voltage: AC , DC
- SIL CL acc. to IEC/EN 62061: 3
- Thermal current Ith max.: 10 A
- Width: 100 mm
- 1- / 2-channel: 1 , 2
- Cat. / PL acc. to EN ISO 13849-1: 4/e
- Nominal voltage: AC , AC/DC
- SIL CL acc. to IEC/EN 62061: 3
- Thermal current Ith max.: 5 A
- Width: 70 mm
- 1- / 2-channel: 1 , 2
- Approvals: UL
- Cat. / PL acc. to EN ISO 13849-1: 4/e
- Nominal voltage: AC , DC
- SIL CL acc. to IEC/EN 62061: 3
- Thermal current Ith max.: 5 A
- Width: 22,5 mm
- 1- / 2-channel: 1 , 2
- Approvals: UL
- Cat. / PL acc. to EN ISO 13849-1: 4/e
- Nominal voltage: AC , AC/DC
- Width: 22,5 mm
- 1- / 2-channel: 1 , 2
- Cat. / PL acc. to EN ISO 13849-1: 4/e
- Nominal voltage: AC/DC
- SIL CL acc. to IEC/EN 62061: 3
- Thermal current Ith max.: 5 A
- Width: 22,5 mm
- 1- / 2-channel: 1 , 2
- Approvals: UL
- Cat. / PL acc. to EN ISO 13849-1: 4/e
- Nominal voltage: DC
- SIL CL acc. to IEC/EN 62061: 3
- Thermal current Ith max.: 8 A
- Width: 22,5 mm
- 1- / 2-channel: 1 , 2
- Cat. / PL acc. to EN ISO 13849-1: 4/e
- Nominal voltage: DC
- SIL CL acc. to IEC/EN 62061: 3
- Thermal current Ith max.: 5 A
- Width: 17,5 mm
- 1- / 2-channel: 2
- Approvals: UL
- Cat. / PL acc. to EN ISO 13849-1: 4/e
- Nominal voltage: DC
- SIL CL acc. to IEC/EN 62061: 3
- Thermal current Ith max.: 8 A
- Width: 17,5 mm
Classic safety relays for monitoring emergency stop and safety gate
The extensive SAFEMASTER product range offers conventional or monofunctional safety relays with emergency stop function. These find their optimal field of application when a plant or machine has a small number of required safety functions. Dold offers compact emergency stop relays from a width of 17.5 mm, variable connection technologies as well as emergency stop modules with time delay or power failure detection. The emergency stop modules are ready-to-connect, type-tested emergency stop modules that can be used in safety applications up to Cat. 4 / PL e or SIL 3. Emergency stop relays are also suitable for use in firing systems according to EN 50156-1.

The application example shows the monitoring of safety door and emergency stop in a machine with an emergency stop relay. The narrow emergency stop module can be used easily and in a space-saving manner in almost any application.